GL Gamma Series - Bushfire Code Compliant – CD566VGL-BFC
This product is no longer available!
Performance Curve - CD566VGL-BFC
Description
The GL Gamma Series, with bushfire code compliance,
has been developed for bushfire prone regions. They feature a high performance backward-curved centrifugal fan and a robust galvanised steel construction.
There are 8 sizes in the range extending from 315 to 710mm diameter.
Features
Quick release toggle clamps provide easy access for cleaning and maintenance.
Designed for vertical discharge applications.
High quality bronze mesh provides ember protection.
Speed-controllable with electronic or auto-transformer controllers (not on CE316VGL-BFC).
Compact, low profile design.
Choice of speeds available.
High performance backward-curved centrifugal fan.
Many 3-phase motors are 2-speed star/delta design.
Can be mounted at angles up to 30°.
Backdraft dampers are an optional extra.
Compliant to AS3959:2009 up to and including BAL-40.
Construction
Cowls are of galvanised steel
Ember protection - bronze mesh with maximum of 2mm aperture
Backward-curved centrifugal impellers
Powder-coating is an optional extra
Motors
Type - external rotor, squirrel cage induction motors
Electricity supply - 230V, single or 415V three-phase, 50Hz
Bearings - sealed-for-life, ball
Speed-controllable using electronic or auto-transformer speed controllers (not CE316VGL-BFC)
Many 3-phase motors are 2-speed star/delta design.
Internal Thermal Protection
All motors are fitted with Internal Thermal Contacts as standard.
Testing
Air flow to ISO5801:1997
Noise tests to BS848:Part 2, 1985
Special Note
Construction of buildings in bushfire prone areas
AS3959:2009, clause 6.6.5(b) "Roof penetrations" states:
Openings in vented roof lights, roof ventilators or vent pipes shall be fitted with ember guards made from a mesh or perforated sheet with a maximum aperture of 2mm, made of corrosion-resistant steel, bronze or aluminium.
Backdraft dampers
Backdraft shutters are an optional extra. The pressure loss across the shutter has to be added to the system pressure before making fan selections.
Kitchen Hood Exhaust Systems
AS/NZS1668.1:1998, Clause 11.2.5 states that, for commercial installations:- "kitchen exhaust fan casings and cowls shall be manufactured from non-combustible materials that have a fusing temperature above 1000°C".
Suggested Specification
The roof ventilators shall be of the GL Gamma Series with bushfire code compliance as designed and manufactured by Fantech Pty Ltd.
Impellers shall be of backward-curved centrifugal design and driven by speed-controllable external rotor motors with integral thermal protection.
They shall be constructed from galvanised steel and be of vertical exhaust design.
Ember protection mesh shall be bronze or steel with openings a maximum of 2mm. The windband shall incorporate
quick-release toggle clamps to provide easy access for cleaning and maintenance.
All data shall be based on tests on a complete assembled unit to ISO5801:1997 for air flow and BS848:Part 2, 1985 for noise.
Technical Data - CD566VGL-BFC
| Speed [rps] |
Avg. dBA @ 3m |
kWatts (Input) |
Amps |
Max.°C |
Approx. Weight [kg] |
| 15 |
54 |
0.65 |
1.4 |
60 |
56 |
| Type |
63 |
125 |
250 |
500 |
1K |
2K |
4K |
8K |
| Inlet |
83 |
83 |
77 |
69 |
66 |
64 |
62 |
61 |
Dimensions
| A |
B |
C |
D |
E |
| 620 |
720 |
60 |
525 |
900 |
*All dimensions in mm, unless otherwise stated
Wiring Diagram
Diagram shown is for single-speed only.
For 2-speed and special motors, contact Fantech for details.