Alpha Relief Air Vents - Bushfire Code Compliant – MRV2-BFC
Location Designation
Project Notes
Alpha Relief Air Vents - Bushfire Code Compliant
Description
The robust Alpha Relief Vents with bushfire code compliance have been designed to control relief air and the pressure within buildings. They may also be used in a ducted system where the fan is mounted remotely to the cowl. They comply with BAL-LOW to BAL-40 of the Australian Standard AS3959:2009 Construction of buildings in bushfire prone areas.
There are 6 models in the range capable of handling air flows from 0.04 to 4.0m3/s.
Features
  • Robust, heavy duty galvanised steel construction.
  • Fitted with high quality bronze mesh to provide protection from burning embers.
  • All units are designed for curb mounting.
  • Can be mounted at angles up to 30°.
  • Can also be used as air intake units. Pressure losses are approximately the same.
  • Compliant to AS3959:2009, upto and including BAL-40
  • Robust, heavy duty galvanised steel construction.
  • Fitted with high quality bronze mesh to provide protection from burning embers.
  • All units are designed for curb mounting.
  • Can be mounted at angles up to 30°.
  • Can also be used as air intake units. Pressure losses are approximately the same.
  • Compliant to AS3959:2009, upto and including BAL-40
Construction
Cowls are of galvanised steel.
Bronze mesh with a maximum of 2mm aperture fitted.
Testing
Performance Curve for Alpha Relief Air Vents - Bushfire Code Compliant MRV2-BFC
 
Alpha Relief Air Vents - Bushfire Code Compliant – MRV2-BFC
Suggested Specification
The roof ventilators shall be of the Alpha Relief Air Vents Series with bushfire code compliance as designed and manufactured by Fantech Pty Ltd.
They shall be constructed from galvanised steel and include ember protection mesh made from bronze or steel with openings a maximum of 2mm. They shall comply with BAL-LOW to BAL-40 of the Australian Standard AS3959:2009 Construction of buildings in bushfire prone areas.
 

Dimensions

Dimension Drawing for Alpha Relief Air Vents - Bushfire Code Compliant MRV2-BFC
ABCDE
37042055357570

*All dimensions in mm, unless otherwise stated

Contacts



OFFICES & AGENTS

Victoria
Fantech Pty. Ltd.
Tel:+61 (03) 9554-7845

New South Wales
Fantech Pty. Ltd.
Tel:+61 (02) 8811-0400

Uniair Distributors Pty. Ltd.
Tel:+61 (02) 4961-6088
Refrigeration and Air Supplies
Tel:+61 (02) 4226-5133

South Australia
Fantech Pty. Ltd.
Tel:+61 (08) 8294-0530

Queensland
Fantech Pty. Ltd.
Tel:+61 (07) 3299-9888
Capricorn Air Conditioning
Tel:+61 (07) 4775-5222

Northern Territory
Fantech Pty. Ltd.
Tel:+61 (08) 7918-5122

Western Australia
Systemaire Pty. Ltd.
Tel:+61 (08) 9209-4999

Tasmania
Major Air Pty. Ltd.
Tel:+61 (03) 62736455

ACT
Idealair Group Pty. Ltd.
Tel:+61 (02) 6280-5511

Auckland
Fantech (NZ) Ltd.
Tel:+64 (09) 444-6266

Christchurch
Fantech (NZ) Ltd.
Tel:+64 (03) 379-8622

Wellington
Fantech (NZ) Ltd.
Tel:+64 (04) 566-0532